首页> 美国卫生研究院文献>Dentistry Journal >New Generation of Fixture–Abutment Connection Combining Soft Tissue Design and Vertical Screw-Retained Restoration: 1-Year Clinical Aesthetics and Radiographic Preliminary Evaluation
【2h】

New Generation of Fixture–Abutment Connection Combining Soft Tissue Design and Vertical Screw-Retained Restoration: 1-Year Clinical Aesthetics and Radiographic Preliminary Evaluation

机译:新一代夹具邻接连接组合软组织设计和垂直螺杆保留恢复:1年临床美学和射线照相初步评价

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

Implant design factors and the abutment connection are correlated with crestal bone stability. The aim of the present study was to evaluate a new type of screw-retained prostheses delivered on tissue-level implants with conical external vertical seal and internal hexagon connection. Implants 4.25 mm in diameter and 10 mm in length (Prama, Sweden and Martina) were placed in partially edentulous patients needing at least one implant in the healed site, having sufficient bone volume. The implant neck was positioned above the bone crest. A healing abutment was placed according to a one-stage approach. Outcome measures were implant and prosthesis survival rate, any complications, marginal bone loss (MBL), periodontal parameters, and pink esthetic score (PES). Overall, 13 patients (4 women and 9 men; mean age 50 ± 22 years) with the same number of implants were treated and followed for one year after loading. At the 12-month follow up, no implant and no prosthesis failed, and no complications were experienced. The mean MBL experienced at the one year follow-up was 0.65 ± 0.48 mm. One year after loading, 2 out of 13 implants present bleeding on probing (15.4%), 4 out of 13 patients presented with plaque at the one year of follow-up (30.8%) and the PES was 10.5 ± 2.3 mm. Within the limitations of the present study, the analyzed implants seem to be a viable treatment option for the rehabilitation of a single tooth gap.
机译:植入物设计因子和基台连接与棱角骨稳定性相关。本研究的目的是评估一种在组织级植入物上提供的新型螺旋保留假体,其具有圆锥形外部垂直密封和内部六角形连接。植入物直径4.25毫米,长度为10毫米(PRAMA,瑞典和Martina)被置于愈合位点至少一个植入物中的部分透明患者,其具有足够的骨体积。植入物颈部位于骨嵴上方。根据一阶段方法放置愈合基台。结果措施是植入和假体存活率,任何并发症,边缘骨丢失(MBL),牙周参数和粉红色美容评分(PES)。总体而言,13名患者(4名妇女和9​​名男性;平均50±22岁),植入数量相同,加载一年后一年。在12个月的跟进时,没有植入物,没有假体失败,没有经历过任何并发症。在一年后续随访的平均MBL为0.65±0.48毫米。加载后一年,13例植入物中的2种探讨(15.4%)出血(15.4%),其中1名患者中的4例患者在一年后呈现出来(30.8%),PE为10.5±2.3毫米。在本研究的局限质内,分析的植入物似乎是用于单齿间隙的恢复的可行处理选择。

著录项

相似文献

  • 外文文献
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号