摘要

Levofloxacin (LF) is a medically important antibiotic drug that is used to treat a variety of bacterial infections. In this study, three highly sensitive and selective carbon paste electrodes (CPEs) were fabricated for potentiometric determination of the LF drug: (i) CPEs filled with carbon paste (referred to as CPE); (ii) CPE coated (drop-casted) with ion-selective PVC membrane (referred to as C-CPE); (iii) CPE filled with carbon paste modified with a plasticizer (PVC/cyclohexanone) (referenced as P-CPE). The CPE was formulated from graphite (Gr, 44.0%) and reduced graphene oxide (rGO, 3.0%) as the carbon source, tricresyl phosphate (TCP, 47.0%) as the plasticizer; sodium tetrakis[3,5-bis(trifluoromethyl)phenyl] borate (St-TFPMB, 1.0%) as the ion exchanger; and levofloxacinium-tetraphenylborate (LF-TPB, 5.0%) as the lipophilic ion pair. It showed a sub-Nernstian slope of 49.3 mV decade−1 within the LF concentration range 1.0 × 10−2 M to 1.0 × 10−5 M, with a detection limit of 1.0 × 10−5 M. The PVC coated electrode (C-CPE) showed improved sensitivity (in terms of slope, equal to 50.2 mV decade−1) compared to CPEs. After the incorporation of PVC paste on the modified CPE (P-CPE), the sensitivity increased at 53.5 mV decade−1, indicating such improvement. The selectivity coefficient (log KLF2+,Fe+3pot.) against different interfering species (Na+, K+, NH4+, Ca2+, Al3+, Fe3+, Glycine, Glucose, Maltose, Lactose) were significantly improved by one to three orders of magnitudes in the case of C-CPE and P-CPE, compared to CPEs. The modification with the PVC membrane coating significantly improved the response time and solubility of the LF-TPB within the electrode matrix and increased the lifetime. The constructed sensors were successfully applied for LF determination in pharmaceutical preparation (Levoxin® 500 mg), spiked urine, and serum samples with high accuracy and precision.
机译:左氧氟沙星(LF)是一种医学上重要的抗生素药物,用于治疗各种细菌感染。在该研究中,制造了三种高度敏感和选择性的碳浆料电极(CPE),用于电位测定LF药物的测定:(i)填充有碳浆料的CPE(称为CPE); (ii)用离子选择性PVC膜(称为C-CPE)涂覆(滴液)的CPE; (iii)用增塑剂(PVC /环己酮)改性碳浆料的CPE(称为P-CPE)。将CPE从石墨(GR,44.0%)和将石墨烯(RGO,3.0%)的石墨源,三氯联基(TCP,47.0%)作为增塑剂的石墨氧化物(Rg。四硫酸钠[3,5-双(三氟甲基)苯基]硼酸酯(ST-TFPMB,1.0%)作为离子交换剂;和左氧嘧啶 - 四苯基硼酸盐(LF-TPB,5.0%)作为亲脂离子对。它在LF浓度范围内为1.0×10-2米至1.0×10-5米的49.3mV十四型-1的子宫颈斜率,检测限为1.0×10-5 m .PVC涂层电极(C -CPE)与CPE相比,显结了改善的灵敏度(在斜坡方面,等于50.2mV十年 - 1)。在改性CPE(P-CPE)上掺入PVC浆料后,灵敏度在53.5 mV十年内-1增加,表明这种改进。针对不同干扰物质(Na +,K +,NH 4 +,Ca 2+,Al3 +,Fe 3,Ca 2+,Al3 +,Fe 3 +,甘氨酸,葡萄糖,麦芽糖,乳糖)的选择性系数(Log Klf2 +,Fe + 3Pot)在情况下显着提高1至三个大小的次数与C-C-CPE和P-CPE相比,与CPE相比。具有PVC膜涂层的改性显着改善了LF-TPB在电极基质内的响应时间和溶解度并增加了寿命。成功地应用于具有高精度和精度的药物制剂(Levoxin®500mg),尖刺尿液和血清样品中的LF测定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号