首页> 外文期刊>American Water Works Association Journal >Integrated Pyrolucite Fluidized Bed-Membrane Hybrid Process for Iron/Manganese Control in Drinking Water
【24h】

Integrated Pyrolucite Fluidized Bed-Membrane Hybrid Process for Iron/Manganese Control in Drinking Water

机译:整合硫铁矿流化床膜混合工艺控制饮用水中的铁/锰

获取原文
获取原文并翻译 | 示例
           

摘要

Although the occurrence of iron (Fe) and manganese (Mn) in drinking water mainly causes organoleptic and/ or operating problems, recent studies have found that Mn intake from water ingestion may lead to intellectual impairment in children and neurological disorders. Even though the secondary maximum contaminant levels of 300 and 50 μg/L were established for Fe and Mn in water, respectively, the concentration as low as 20 μg/L may give rise to discoloration of water. The traditional treatment strategy for Fe/Mn control includes oxidation of dissolved species to particulate forms followed by depth filtration.
机译:尽管饮用水中铁(Fe)和锰(Mn)的存在主要引起感官和/或操作问题,但最近的研究发现,食水摄入的锰可能导致儿童智力障碍和神经系统疾病。即使水中的Fe和Mn的二级最大污染物含量分别为300和50μg/ L,但低至20μg/ L的浓度也可能导致水变色。 Fe / Mn控制的传统处理策略包括将溶解的物质氧化为颗粒形式,然后进行深度过滤。