首页> 外文期刊>Annals of nuclear energy >Control rod assembly drops to fully inserted position`
【24h】

Control rod assembly drops to fully inserted position`

机译:控制杆组件下降到完全插入的位置`

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This paper describes validation of a computer model that has been developed for VVER 440 Nuclear Power Plant (NPP) for use with RELAP5/MOD 3.2 computer code in the analysis of the following transient: "Control rod assembly drops to fully inserted position". This validation is a process that compares the analytical results obtained by RELAP5/ MOD3.2 model of the VVER 440 with experimental transient data received from Kozloduy NPP, Unit #2. The model of VVER 440 was developed at the the Institute for Nuclear Research and Nuclear Energy for analyses of operational occurrences, abnormal events and design basis scenarios. It will provide a significant analytical capability for the Bulgarian technical specialists located at the Kozloduy NPP. The criteria used in selecting transient are: importance to safety, availability and suitability of data followed by suitability for RELAP5 code validation. The comparisons between the RELAP5 results and the test data indicate good agreement.
机译:本文描述了为VVER 440核电站(NPP)开发的计算机模型的验证,该模型可与RELAP5 / MOD 3.2计算机代码一起使用,以分析以下瞬态现象:“控制杆组件下降到完全插入的位置”。此验证是一个过程,该过程将VVER 440的RELAP5 / MOD3.2模型获得的分析结果与从Kozloduy NPP,单元#2收到的实验瞬态数据进行比较。 VVER 440的模型是由核研究所和核能研究所开发的,用于分析运行事件,异常事件和设计基础方案。它将为位于Kozloduy NPP的保加利亚技术专家提供重要的分析能力。选择瞬态时使用的标准是:对数据安全性,可用性和适用性的重要性,然后是RELAP5代码验证的适用性。 RELAP5结果与测试数据之间的比较表明一致性良好。