首页> 外文期刊>Applied Computational Electromagnetics Society journal >An Empirical Modeling of Electromagnetic Pollution on a University Campus
【24h】

An Empirical Modeling of Electromagnetic Pollution on a University Campus

机译:大学校园电磁污染的经验模型

获取原文
获取原文并翻译 | 示例
           

摘要

In this study, electric field strength (E) levels were measured on Ondokuz Mayis University's Kurupelit Campus and Faculty of Medicine Hospital in Samsun, Turkey between years 2013-2015. 840 short term and two long term measurements were performed using PMM-8053 and SRM-3006 at 60 different locations of which 30 were on both the campus and hospital. The results show that the measured E levels are far below the limits that are determined by ICNIRP. Based on the measurement analysis, a novel empirical model that allows characterizing the total E of medium using three main electromagnetic (EM) sources with 99.7% accuracy was proposed. Then other new models to estimate main distribution of total E were suggested. With the use of these models, E values of main pollution sources can be estimated with 95.2% accuracy and easily lead to prediction of future EM pollution levels.
机译:在这项研究中,在2013年至2015年之间,对Ondokuz Mayis大学的Kurupelit校园和土耳其Samsun医学院的医院测量了电场强度(E)。使用PMM-8053和SRM-3006在60个不同的位置进行了840次短期和两次长期测量,其中30个在校园和医院中。结果表明,测得的E水平远低于ICNIRP确定的极限。基于测量分析,提出了一种新的经验模型,该模型可以使用三个主要电磁(EM)源以99.7%的准确度来表征介质的总E。然后提出了其他新的模型来估计总E的主要分布。使用这些模型,可以以95.2%的准确度估算主要污染源的E值,并且可以轻松预测未来的EM污染水平。