Integrated Interaction Diagrams for Sections Subjected to Axial Force and Bending Moment According to the American Concrete Institute and the Saudi Building Code

机译:根据美国混凝土研究所和沙特建筑规范,对轴向力和弯矩进行轴向力和弯矩的综合交互图

获取原文
获取原文并翻译 | 示例
           

摘要

The Saudi Building Code for the design of concrete structures (SBC304) is identical to the American Concrete Institute metriccode (ACI318M-19); therefore, any design aids developed for one of them could be used for the other. When designing areinforced concrete section that is subjected to an axial force accompanied by a bending moment, an interaction diagramis needed. Most textbooks provide interaction diagrams based on imperial units and only a few provide these interactiondiagrams based on metric units. Moreover, the new proposed interaction diagrams have advantages compared with theavailable diagrams in the textbooks. They do not only consider axial compression forces but also tension forces. The portionabove the maximum allowable axial compression force is not displayed in these diagrams to prevent users from using thispart of the diagrams since according to the code requirements, which is not permissible. In addition, these diagrams allow oneto use ratios of compression to tension reinforcement different than 1.0, which is the only ratio available in the textbooks. Awide range of ratios for the lever arm of extreme reinforcement to the section depth is presented in the diagrams with a 0.05step. Also, numerous values of concrete strength (f_c~) ranges are covered. Finally, along with the nominal interaction diagramplots, ultimate (design) interaction diagrams are created as well, which provide easier usage. To verify the accuracy of theseinteraction diagrams, several examples from many textbooks were resolved using these diagrams and the results were shownto be compatible.
机译:沙特建筑规范的混凝土结构(SBC304)与美国混凝土研究所公制相同代码(ACI318M-19);因此,对于其中一个开发的任何设计辅助装置都可以用于另一个。在设计A时经受轴向力的钢筋混凝土部分伴随着弯矩,互动图是必要的。大多数教科书提供基于英制单位的交互图,只有少数人提供这些互动基于度量单位的图表。此外,新的拟议互动图与相比有优势文本书中的可用图。它们不仅考虑轴向压缩力,而且仅考虑张力。一部分在这些图中不显示最大允许轴向压缩力以防止用户使用此自根据代码要求以来,图的一部分,这是不允许的。此外,这些图允许一个使用压缩比率与1.0不同的张力增强,这是教科书中唯一可用的比率。一种在图0.05的图表中介绍了截面深度的极端加固杠杆臂的各种比率范围步。此外,覆盖了许多混凝土强度(F_C〜)范围的值。最后,以及名义交互图绘图,终极(设计)交互图也是创建的,这提供了更容易的使用。验证这些的准确性交互图,使用这些图来解析来自许多教科书的若干示例,并显示了结果要兼容。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号