摘要

It is sometimes desired to place building insulation in the centre of a wall cavity, to get the advantage of extra air spaces in the insulation system. Recently BRANZ carried out a series of tests to determine exactly what merit this simple action might have, for a range of different edge gaps. The results are likely to be of some importance to designers, and show simple specific design criteria that will have to be met to ensure that this practice would be effective. If these limits are not met, then rather than enhancing the performance, the wall R-Value will instead be halved. The measurements in this instance concerned EPS board insulation, but previous work dealing with fibreglass and reflective laminates is also referred to.
机译:有时需要将建筑物的隔热材料放置在墙体腔的中心,以获得隔热系统中多余空气空间的优势。最近,BRANZ进行了一系列测试,以确定对于一系列不同的边缘间隙,此简单操作可能具有什么优点。结果可能对设计者来说很重要,并显示了必须满足的简单特定设计标准,以确保这种做法有效。如果不满足这些限制,那么墙R值将提高一半,而不是提高性能。在这种情况下,测量涉及EPS板的绝缘,但也涉及玻璃纤维和反射性层压板的先前工作。