The variety of technical solutions providing protection to operators of electrical engineering product (EEP) against electric shock isn't reflected in the current standards of the IEC (International Electrical Commission), by indexation of EEP with classes of electrical safety by protection method. Nowadays, such technical solutions are based on the following methods of operator protection corresponding to the following IEC safety classes: 1. Protection by insulations - main, dual, reinforced (strength- ened). Protection by main insulation is covered by IEC class 0. Protection by either dual or reinforced (strengthened) insulation is covered by IEC class Ⅱ; 2. Protection by insulation in combination with grounding of metal non-conductive parts is covered by IEC classes 01 and Ⅰ; 3. Protection by safe super low voltage of power supply is cov- ered by IEC class Ⅲ.
机译:IEC(国际电气委员会)的当前标准未通过将EEP标记为带有防护方法的电气安全类别来反映为电气工程产品(EEP)的操作员提供防触电保护的各种技术解决方案。如今,这种技术解决方案基于与以下IEC安全等级相对应的以下操作员保护方法:1.通过绝缘进行保护-主,双,加强(加强)。 IEC等级0涵盖了通过主绝缘进行的保护。IEC等级II涵盖了采用双重绝缘或加强(加强)绝缘的保护; 2.绝缘保护结合金属非导电部件的接地符合IEC等级01和Ⅰ; 3.符合IECⅢ级标准,提供安全的超低压电源保护。