Normal Range of Left Ventricular 2-Dimensional Strain – Japanese Ultrasound Speckle Tracking of the Left Ventricle (JUSTICE) Study –

机译:左心室二维应变的正常范围–左心室的日本超声斑点跟踪(JUSTICE)研究–

获取原文
           

摘要

Background: ?To determine the normal range of left ventricular (LV) 2- dimensional (2-D) strain and vendor-specific differences, a multicenter prospective 2-D strain study endorsed by the Japanese Society of Echocardiography was conducted. Methods and Results: ?2-D speckle tracking analysis was performed on 817 healthy subjects (age range, 0–88 years); the images included 3 LV short axis and 3 apical views using an ultrasound system from 1 of the 3 different vendors (V1, n=333; V2, n=330; V3, n=337). With the 2-D speckle tracking software from each vendor, radial, circumferential and longitudinal strain were measured using an 18-segment model. Inter-vendor variability was also assessed in a subset of subjects. The feasibility for 2-D strain measurements was different among the 3 vendors (V1, 83%; V2, 70%; V3, 88%, P1, 54.6±12.6%; V2, 36.3±8.2%; V3, 51.4±8.0%), circumferential (V1, –22.8±2.9%; V2, –22.2±3.2%; V3, –30.5±3.8%), and longitudinal (V1, –21.3±2.1%; V2, –18.9±2.5%; V3, –19.9±2.4%) strain measurements were significantly different for each of the vendors. Segmental strain was also different between the 3 vendors. On inter-vendor analysis, vendor agreement ranged from mild to moderate. Conclusions: ?Reference values are provided for normal 2-D strain for 3 different ultrasound vendors. Due to a low inter-vendor agreement, 2-D strain data are not interchangeable when conducting a longitudinal follow-up or a cross-sectional assessment of LV function.??(Circ J?2012; 76: 2623–2632)
机译:背景:为了确定左心室(LV)二维(2-D)应变的正常范围和供应商特定的差异,日本超声心动图学会认可了一项多中心前瞻性二维应变研究。方法和结果:对817名健康受试者(年龄在0-88岁)进行了2-D斑点跟踪分析。该图像包括3个不同供应商中的1个的超声系统使用的3个LV短轴和3个顶视图(V 1 ,n = 333; V 2 ,n = 330 ; V 3 ,n = 337)。使用每个供应商提供的二维斑点跟踪软件,使用18段模型测量径向,周向和纵向应变。还评估了部分受试者的供应商间差异。 3个供应商之间进行二维应变测量的可行性有所不同(V 1 ,83%; V 2 ,70%; V 3 ,88%,P1 ,54.6±12.6%; V 2 ,36.3±8.2%; V 3 ,51.4±8.0%),圆周(V < sub> 1 ,– 22.8±2.9%; V 2 ,– 22.2±3.2%; V 3 ,– 30.5±3.8%)和纵向( V 1 ,– 21.3±2.1%; V 2 ,– 18.9±2.5%; V 3 ,– 19.9±2.4%)应变测量对于每个供应商而言,都有很大的不同。 3家供应商之间的细分压力也有所不同。在供应商间分析中,供应商协议的范围从轻度到中度。结论:?为3个不同的超声供应商提供了正常二维应变的参考值。由于供应商之间的协议较低,在进行纵向随访或对LV功能进行横截面评估时,二维应变数据不可互换。(Circ J?2012; 76:2623-2632)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号