首页> 外文期刊>Clinical ophthalmology >Adaptive optics assisted visualization of thickened retinal arterial wall in a patient with controlled malignant hypertension
【24h】

Adaptive optics assisted visualization of thickened retinal arterial wall in a patient with controlled malignant hypertension

机译:自适应光学辅助可视化控制恶性高血压患者的视网膜动脉壁增厚

获取原文
           

摘要

Purpose: We aimed to visualize the retinal arterial wall thickness, assisted by noninvasive adaptive optics scanning laser ophthalmoscopy (AO-SLO).Methods: The arterial wall thickness was measured and compared between one normal subject and one patient suffering from malignant hypertensive retinopathy.Results: Increased arterial wall thickness was revealed with a newly developed AO-SLO system, in a retinal artery of 1-papilla diameter temporal inferior to the optic disc. The average wall thickness, with hypertension, was 18.7 μm, and the wall-to-lumen ratio was 0.44, both bigger than normal.Conclusion: AO-SLO enabled us to evaluate the retinal wall thickness in the hypertensive patient. The arterial walls were thickened compared with normal. AO-SLO may facilitate future noninvasive study of arterial walls in human medicine.
机译:目的:我们旨在通过无创自适应光学扫描激光检眼镜(AO-SLO)来观察视网膜动脉壁厚度。方法:测量并比较一名正常受试者和一名患有恶性高血压视网膜病变的患者的动脉壁厚度。 :在新开发的AO-SLO系统中,在视乳头下1孔直径的视网膜动脉中发现了动脉壁厚度的增加。高血压患者的平均壁厚为18.7μm,壁腔比为0.44,均比正常人大。结论:AO-SLO使我们能够评估高血压患者的视网膜壁厚。与正常相比,动脉壁增厚。 AO-SLO可能会促进未来人类医学中动脉壁的非侵入性研究。