A comparative evaluation of the Abbott AxSYM and DPC Immulite random-access analyzers was performed using 497 prospectively collected serum samples. These samples were sent to the laboratory for routine antenatal screening for hepatitis B surface antigen and immunoglobulin G (IgG) and IgM antibodies to Toxoplasma gondii and rubella virus. The overall agreement between the two assay systems ranged from 97.4 to 100%. After discrepancy analysis, the outcome in terms of sensitivity and specificity varied from 98.2 to 100% for all but one of the assays tested. The AxSYM rubella virus IgG assay tended to report protective or indeterminate antibody levels in 1% of the samples. This shortcoming might be overcome by raising the cutoff of the microparticle enzyme immunoassay system.
机译:使用497个预期收集的血清样本对Abbott AxSYM和DPC Immulite随机访问分析仪进行了比较评估。这些样本被送往实验室,以进行常规的产前筛查,以检测乙型肝炎表面抗原和免疫球蛋白G(IgG)以及针对弓形虫和风疹病毒的IgM抗体。两种测定系统之间的总体一致性为97.4%至100%。经过差异分析后,除一种测试外,所有灵敏度和特异性的结果在98.2%到100%之间变化。 AxSYM风疹病毒IgG分析倾向于报告1%样品中的保护性或不确定抗体水平。该缺点可以通过提高微粒酶免疫测定系统的临界值来克服。

著录项