Aim:The purpose of this study was to evaluate and compare the tensile bond strength and microleakage of Fuji IX GP, Fuji II LC, and compoglass and to compare bond strength with degree of microleakage exhibited by the same materials.Materials and Methods:Occlusal surfaces of 96 noncarious primary teeth were ground perpendicular to long axis of the tooth. Preparations were distributed into three groups consisting of Fuji IX GP, Fuji II LC and Compoglass. Specimens were tested for tensile bond strength by mounting them on Instron Universal Testing Machine. Ninety-six primary molars were treated with Fuji IX GP, Fuji II LC, and compoglass on box-only prepared proximal surface. Samples were thermocycled, stained with dye, sectioned, and scored for microleakage under stereomicroscope. ANOVA and Bonferrani correction test were done for comparisons. Pearson Chi-square test and regression analysis were done to assess the association between the parameters.Results:Compoglass showed highest tensile strength and Fuji II LC showed least microleakage. There was a significant difference between the three groups in tensile strength and microleakage levels. The correlation between tensile strength and microleakage level in each group showed that there was a significant negative correlation only in Group 3.Conclusion:Fuji II LC and compoglass can be advocated in primary teeth because of their superior physical properties when compared with Fuji IX GP.
机译:目的:本研究的目的是评估和比较Fuji IX GP,Fuji II LC和复合玻璃的拉伸粘结强度和微渗漏,并比较相同材料所表现出的粘结强度和微渗漏程度。材料与方法:咬合面垂直于牙齿长轴的96颗非龋齿乳齿中。将制剂分为三组,分别为Fuji IX GP,Fuji II LC和Compoglass。通过将样品安装在Instron万能试验机上来测试样品的抗拉强度。用Fuji IX GP,Fuji II LC和复合玻璃在仅准备好的近端表面上处理了96个主要磨牙。将样品热循环,用染料染色,切片,并在立体显微镜下对微渗漏进行评分。比较进行方差分析和Bonferrani校正测试。结果:复合玻璃纤维的抗拉强度最高,Fuji II LC的微渗漏最少,进行了Pearson卡方检验和回归分析。三组之间的拉伸强度和微渗漏水平存在显着差异。每组的拉伸强度与微渗漏水平之间的相关性表明,仅在第3组中存在显着的负相关性。结论:与II型相比,Fuji II LC和compoglass由于其优越的物理性能而可在乳齿中使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号