Currently, it is desired to incorporate force feedback into medical robots. In this study, a three-axis load measurement sensor mounted on the tip of forceps was developed. The newly developed sensor electrodes are threedimensionally arranged. From the simulation, the effect of the taper angle on the load measurement was revealed. A taper angle θ =π /4 rad is the most suitable angle for the measurement of the normal and shear loads. As a result, by measuring the normal load applied to each zone, this sensor can calculate the normal load and shear load.
机译:当前,期望将力反馈结合到医疗机器人中。在这项研究中,开发了一种安装在钳子尖端的三轴负载测量传感器。新开发的传感器电极在三维上排列。通过仿真,可以看出锥角对载荷测量的影响。锥角θ= π/ 4 rad是测量法向载荷和剪切载荷的最合适角度。结果,通过测量施加到每个区域的法向载荷,该传感器可以计算法向载荷和剪切载荷。