首页> 外文期刊>International Journal of Coal Science & Technology >Experimental study on performance of contra-rotating axial flow fan
【24h】

Experimental study on performance of contra-rotating axial flow fan

机译:对流轴流风机性能的实验研究

获取原文
           

摘要

Abstract Contra-rotating axial flow fan is a kind of the vital equipment in coal mines. Their work conditions directly affect the safety of staff and production. In the paper, the performance of the contra-rotating axial flow fan is experimentally investigated. The study is focused on the fan performance, the shaft power and the match between the motor and fan efficiency at different blade angles. The results show that the blade angle 43°/26° has the best aerodynamic performance. The first engine has a greater impact on the fan than the second one. The blade angle with the best aerodynamic performance does not necessarily correspond to the one with the best match between the motor and fan efficiency. The blade angle 43°/24° is the best choice for the operation of the fan in the present study.
机译:摘要对转轴流风机是煤矿中的重要设备。他们的工作条件直接影响员工和生产的安全。本文通过实验研究了反向旋转轴流风机的性能。该研究的重点是风扇性能,轴功率以及在不同叶片角度下电动机与风扇效率之间的匹配。结果表明,叶片角43°/ 26°具有最佳的空气动力学性能。与第二个相比,第一个引擎对风扇的影响更大。具有最佳空气动力学性能的叶片角不一定与电动机和风扇效率之间具有最佳匹配的叶片角相对应。在本研究中,叶片角43°/ 24°是风扇工作的最佳选择。