首页> 外文期刊>International Journal of Electrochemical Science >Electrochemical Quantification of CK-MB in Serum Based on Immunoassay
【24h】

Electrochemical Quantification of CK-MB in Serum Based on Immunoassay

机译:基于免疫测定的血清中CK-MB的电化学定量

获取原文
           

摘要

Creatine kinase isoenzyme (CK-MB) is a cardiac biomarker for post-PCI recovery evaluation. This work describes a novel biosensor concept that can be used to quantify enzyme levels where the substrate is immobilized directly on the glassy carbon electrode (GCE). The phosphorylated form of creatine (PC) was immobilized on the electrode with cysteamine (Cys) by a self-assembling monolayer technique. Electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) studies were used to follow the chemical modification process. The proposed electrochemical sensor could detect MB-CK at a range from 0.1 to 2000 ng/mL. The detection limit was determined to be 0.04 ng/mL.