A problem of uncontrolled internal corrosion of over 20 mpy was root cause analyzed within a systemof pipelines connecting a set of oil wells onshore central Gulf of Mexico coastline. The root causeanalysis was focused on a detailed characterization of the gas, mostly methane, and liquid phases,mostly genic waters as well as CO2, H2S, chlorides and MIC bacteria. The metallurgy of the corrosiondamage over the steel pipeline involving both zone of uniform corrosion as well as special points oflocalized corrosion. In the past these pipelines received unsuccessful chemical treatments. Both theinhibitor and the dosage were not available. A trial of a new palm oil based corrosion inhibitor wasperformed. The corrosion inhibitor passed successful testing in the laboratory employingelectrochemical testing by linear polarization resistance as well as harmonic analysis. The corrosioninhibitor formulation was furthermore adapted for massive fabrication involving a set of parallelvariables from pipeline engineering such as foam formation elimination, not gel formation and other.The program was conducted producing improvements from the onset. Corrosion inhibitor injectionwas immediately and a program of pipeline cleaning was launched. In the first four months of the newcorrosion inhibitor solution the results produced the desired target of overall compliance to the internalpipeline corrosion control specification below 2 mpy.
机译:在连接墨西哥湾中部海岸线沿岸的一组油井的管道系统中,分析了超过20 mpy的内部腐蚀不受控制的问题的根本原因。根本原因分析的重点是对气体(主要是甲烷)和液相(主要是纯净水)以及CO2,H2S,氯化物和MIC细菌的详细表征。钢管上腐蚀损坏的冶金学涉及均匀腐蚀区域和局部腐蚀的特殊点。过去,这些管道没有经过化学处理。抑制剂和剂量均不可用。进行了一种新的基于棕榈油的缓蚀剂的试验。该腐蚀抑制剂在实验室中通过了通过线性极化电阻的电化学测试以及谐波分析,通过了成功的测试。此外,该缓蚀剂配方还适用于大规模生产,涉及管道工程中的一组平行变量,例如消除泡沫形成,不形成凝胶等。该程序从一开始就产生了改进。立即注入腐蚀抑制剂,并启动了管道清洁程序。在新型缓蚀剂解决方案的前四个月中,结果产生了对内部管道腐蚀控制规格低于2 mpy的总体合规性的预期目标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号