...
首页> 外文期刊>Endoscopy International Open >Electromagnetic assisted endoscopic submucosal dissection is more efficient than water-jet assisted and conventional ESD in experimental model
【24h】

Electromagnetic assisted endoscopic submucosal dissection is more efficient than water-jet assisted and conventional ESD in experimental model

机译:在实验模型中,电磁辅助内镜黏膜下剥离术比喷水辅助和常规ESD更有效

获取原文
           

摘要

Background and study aims The adequate visualization of the dissection line, inside the submucosal layer, supposes the main challenging issue in ESD. For this reason, several counter traction methods have been developed focused on overcoming this handicap.?One of which, Magnetic anchor guided?–?ESD (MG-ESD) is an attractive alternative. However, the usefulness of this approach has been scarcely assessed and compared with other ESD strategies. Therefore, the aim of this study is to compare three different ESD alternatives in experimental faction. Methods This was a prospective non-randomized study, in which three different ESD techniques were performed in an ex-vivo gastric porcine model by an endoscopist slight expertise in ESD: conventional ESD, waterjet assisted ESD and MG-ESD. MG-ESD was performed using two different magnets: inner Neodymiun ringed shape magnet attached to the simulated lesions by an endoclip and external electromagnet connected to a Single Output Adjustable 24V/0.3A Power Supply Unit. Results Forty-six ESD procedures were performed: 24 conventional ESD, 12 waterjet-assisted ESD and 10 MG-ESD. Average size of the simulated lesions was 33.86?mm. No differences in terms of safety and efficacy were registered between the three approaches. Nevertheless, MG-ESD proved to be faster and more efficient than conventional ESD and water-jet assisted ESD (min per cm2 10.85 vs. 7.43 vs. 3,41; P =?0.001). Conclusions MG-ESD could be a feasible alternative to conventional ESD even at the beginning of the learning curve. Therefore, researches focused on developing appropriate ESD magnetic devices and further comparative studies must be promoted, in order to assess the reliable usefulness of the magnet-assistance in ESD.
机译:背景和研究目标黏膜下层内部解剖线的充分可视化是ESD的主要挑战。因此,已经开发了几种克服这种障碍的反牵引方法。其中一种是电磁锚导向的静电防护(MG-ESD),是一种有吸引力的选择。但是,这种方法的实用性几乎没有得到评估,并与其他ESD策略进行了比较。因此,本研究的目的是比较实验派别中的三种不同的ESD替代方案。方法这是一项前瞻性非随机研究,其中由内镜医师在ESD方面稍有专长,在离体胃猪模型中进行了三种不同的ESD技术:常规ESD,水刀辅助ESD和MG-ESD。 MG-ESD使用两种不同的磁体执行:内部Neodymiun环形磁体通过内窥镜连接到模拟病灶,外部电磁体连接到单输出​​可调24V / 0.3A电源单元。结果进行了46次ESD程序:24常规ESD,12喷水辅助ESD和10 MG-ESD。模拟病变的平均大小为33.86?mm。三种方法之间在安全性和功效方面没有差异。尽管如此,事实证明,MG-ESD比传统的ESD和喷水辅助的ESD更快,更高效(min / cm 2 10.85 vs. 7.43 vs. 3.41; P = 0.001)。结论即使在学习曲线开始时,MG-ESD仍然可以替代传统ESD。因此,为了评估电磁辅助在ESD中的可靠效用,致力于开发合适的ESD磁性器件的研究必须得到进一步发展。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号