首页> 外文期刊>Fisioterapia em Movimento >Reliability of the endurance test for the erector spinae muscle
【24h】

Reliability of the endurance test for the erector spinae muscle

机译:竖脊肌耐力测试的可靠性

获取原文
           

摘要

Introduction: The low resistance of the erector spinae has been seen as a risk factor for developing chronic low back pain. The test of the erector spinae muscle endurance advocated by Biering-Sorensen has been used to assess the strength of the erector spinae muscle. Modifications of the measuring instrument require reliability studies. Objective: To evaluate the measurement of the erector spinae muscle endurance and the standard error of measurement (SEM) of the modified Biering-Sorensen test of erector spinae in women with chronic low back pain. Methods: Forty-eight sedentary women, aged 52 ?±7, suffering from chronic low back pain, were tested. The position adopted was the prone position without the trunk on the examining table. Fixations were performed with straps at the ankles, knees and pelvis. The patient was instructed to maintain the shoulder blades in contact with the stadiometer as long as possible. The measurement was repeated, with measures 15 minutes apart. Results: Considering the confidence limits of Bland & Altman, - 40 and 68 seconds, the SEM was13 seconds and SEM% was 22. The ICC = 0.87 with p = 0.001. The first test was equal to 54 ?± 36 seconds, and the retest = 67 ?± 40 seconds. Conclusion: The endurance test of the erector spinae showed moderate reliability. Therefore, we suggest that, despite its applicability in clinical practice, the results should be interpreted carefully because the differences in mean erector spinae endurance of up to 13 seconds may be related to measurement error.
机译:简介:竖脊肌抵抗力低下已被视为发展慢性腰背痛的危险因素。 Biering-Sorensen提倡的竖脊肌耐力测试已用于评估竖脊肌的力量。修改测量仪器需要进行可靠性研究。目的:评估慢性腰背痛妇女的竖脊肌耐力的测量值和改良的Biering-Sorensen竖脊肌测验的标准误差(SEM)。方法:测试了48位久坐不动的52岁±7岁女性,患有慢性下腰痛。采取的姿势是俯卧姿势,检查台上没有躯干。用脚踝,膝盖和骨盆的固定带进行固定。指示患者尽可能使肩blade骨与测速仪保持接触。重复测量,相隔15分钟。结果:考虑到Bland&Altman的置信限-40和68秒,SEM为13秒,SEM%为22。ICC= 0.87,p = 0.001。第一次测试等于54±36秒,重新测试= 67±40秒。结论:竖脊肌的耐力测试显示出中等的可靠性。因此,我们建议,尽管其在临床实践中具有适用性,但应仔细解释结果,因为最长13秒的平均直立脊柱耐力差异可能与测量误差有关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号