Some discharge phenomena seriously damaged the secondary mirror for Thomson scattering diagnostics, which was located outside the vacuum vessel. In this paper, the surface damages recorded on the mirror are observed in detail with an optical microscope. Many fine trails were found on the surface. The trails could be categorized into two different types with respect to the trail width. The mechanisms to lead the damages were discussed based on the observation. This study issues warning on the components to be installed in future fusion devices both inside and outside the vacuum vessel.
机译:一些放电现象严重损坏了位于真空容器外部的用于汤姆森散射诊断的辅助镜。在本文中,用光学显微镜详细观察了镜子上记录的表面损伤。在表面上发现了许多细小痕迹。关于路径宽度,路径可以分为两种不同的类型。在观察的基础上讨论了导致损害的机制。这项研究对即将在真空容器内外的未来融合设备中安装的组件发出警告。