首页> 外文期刊>Quimica nova >Lead(II) removal in continous systems by vapor activated carbon
【24h】

Lead(II) removal in continous systems by vapor activated carbon

机译:连续系统中通过蒸气活性炭去除铅(II)

获取原文
           

摘要

Fixed-bed column studies were undertaken to evaluate the performance of a commercial Brazilian activated carbon in removing Pb(II) from aqueous environment. Breakthrough points were found out for the metal adsorption by varying different operating parameters like feed concentrations (10 and 20 mg L-1) and bed heights (0.5, 1.5 and 2.8 cm). A good agreement was observed between the experimental data and the values predicted by the bed depth service time (BDST) model. Regeneration of the exhausted columns was possible with HCl, and the adsorption capacity was maintained after three adsorption-desorption cycles.
机译:进行了固定床色谱柱研究,以评估巴西商业活性炭从水性环境中去除Pb(II)的性能。通过改变不同的操作参数(例如进料浓度(10和20 mg L-1)和床高(0.5、1.5和2.8 cm))发现了金属吸附的突破点。实验数据与床深服务时间(BDST)模型预测的值之间观察到很好的一致性。用HCl可使废柱再生,并在三个吸附-解吸循环后保持吸附能力。