首页> 外文期刊>Journal of Basic and Applied Physics >Determination of Potassium and Magnesium in the Glass Sample by Neutron Activation Technique
【24h】

Determination of Potassium and Magnesium in the Glass Sample by Neutron Activation Technique

机译:中子活化技术测定玻璃样品中的钾和镁

获取原文
           

摘要

Elemental analysis of potassium and magnesium in the glass sample with reference to IAEA standard has been carried out simultaneously by using neutron activation and off-line gamma ray spectrometric technique. The amount of potassium and magnesium in the glass sample was also obtained from the composition of glass sample given by the supplier and compared with the experimental value of the present work. It was found that the experimental value for magnesium is in good agreement with the theoretical value. However, in the case of potassium the experimental value is around ten times higher than the theoretical value. Reason for this discrepancy has been investigated.
机译:通过使用中子活化和离线伽玛射线能谱技术同时进行了参照国际原子能机构标准对玻璃样品中钾和镁的元素分析。玻璃样品中钾和镁的含量也可从供应商提供的玻璃样品的组成中获得,并与本工作的实验值进行比较。发现镁的实验值与理论值良好吻合。但是,在钾的情况下,实验值比理论值高约十倍。已对此差异的原因进行了调查。