Background class='Para'>Anatomic reduction of intra-articular fractures of the tibial plateau and distal radius can be difficult to achieve. Treatment goals are centered on resto'/> Inflation osteoplasty: in vitro evaluation of a new technique for reducing depressed intra-articular fractures of the tibial plateau and distal radius
首页> 外文期刊>Journal of orthopaedics and traumatology: official journal of the Italian Society of Orthopaedics and Traumatology >Inflation osteoplasty: in vitro evaluation of a new technique for reducing depressed intra-articular fractures of the tibial plateau and distal radius
【24h】

Inflation osteoplasty: in vitro evaluation of a new technique for reducing depressed intra-articular fractures of the tibial plateau and distal radius

机译:膨胀性骨成形术:一种减少胫骨平台和distal骨远端凹陷性关节内骨折的新技术的体外评估

获取原文
           

摘要

class="Heading">Background class="Para">Anatomic reduction of intra-articular fractures of the tibial plateau and distal radius can be difficult to achieve. Treatment goals are centered on restoring the native anatomy and articular congruency. Several surgeons in the USA have begun using an inflatable bone tamp to reduce these fracture patterns. The concept is built on the success of the tamp in kyphoplasty of the spine, but it has yet to be tested in the lab for use in the extremities. We performed an investigation into the safety and efficacy of using an inflatable bone tamp for intra-articular fracture reduction of the tibial plateau and distal radius. class="Heading">Materials and methods class="Para">Paired cadaveric specimens were obtained for a total of six proximal tibias and six distal radii. Intra-articular depression-type fractures were created in all specimens. The inflatable bone tamp was then used to reduce the depression. For comparison, the tibias were fractured on the medial and lateral side and a conventional metal tamp was used on the contralateral side of the balloon. Fine-cut micro-computed tomography (CT) scans were performed on all intact specimens, which were then fractured, and again after fracture reduction. CT data was used to measure the amount of restoration of the normal anatomy and to compare the effectiveness of the balloon to conventional methods. class="Heading">Results class="Para">The inflatable bone tamp was equivalent to conventional methods in large, minimally displaced fracture fragments and proved superior when comminution was present at the articular surface. No instances of overreduction or penetration into the joint were encountered with the balloon, whereas this was a common occurrence with conventional metal tamps. The inflatable tamp was successful in reducing all distal radius fractures without complication. class="Heading">Conclusion class="Para">Anatomic reduction of impacted articular fractures should be the goal of any treating surgeon. In our cadaveric models, we have shown the inflatable bone tamp to be safe and effective in reducing depressed articular fractures around the tibial plateau and distal radius. The balloon offers the advantage of being minimally invasive and creating a symmetric, contained defect to hold bone filler for subchondral support.
机译:class =“ Heading”>背景 class =“ Para”>很难实现胫骨平台和远端radius骨的关节内骨折的解剖复位。治疗目标集中在恢复自然解剖结构和关节全合上。美国的几位外科医生已开始使用充气式骨夯来减少这些骨折模式。该概念建立在夯实器在脊柱后凸成形术上的成功基础上,但尚未在实验室中进行测试以用于四肢。我们对使用充气式骨夯来减少胫骨平台和远端radius骨的关节内骨折的安全性和有效性进行了调查。 class =“ Heading”>材料和方法 获得配对的尸体标本,共计六个胫骨近端和六个远端半径。在所有标本中都产生了关节内凹陷型骨折。然后,使用可膨胀的骨夯来减轻凹陷。为了进行比较,胫骨在内侧和外侧断裂,在气囊的对侧使用传统的金属捣固器。对所有完整的标本进行精细切割的计算机断层扫描(CT)扫描,然后将其断裂,并在骨折复位后再次进行。 CT数据用于测量正常解剖结构的恢复量,并将球囊与常规方法的有效性进行比较。 class =“ Heading”>结果 class =“ Para” >可充气的骨夯与常规方法等效,适用于大的,最小位移的骨折碎片,并且当在关节表面存在粉碎时被证明是优越的。球囊没有遇到过度复位或渗入关节的情况,而这是传统金属夯实的常见现象。充气式夯实术可以成功地减少所有远端radius骨骨折而无并发症。 class =“ Heading”>结论 class =“ Para”>以解剖学方式减少受影响的关节骨折应该是我们的目标任何外科医生。在我们的尸体模型中,我们显示了可充气的骨夯在减少胫骨平台周围和远端radius骨凹陷的关节骨折方面是安全有效的。球囊具有微创性和产生对称的封闭缺陷的优点,可容纳骨填充物用于软骨下支撑。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号