Based on analysis of the reason and process of condensation on ceiling radiant cooling panels, two kinds of arrangement of detectors are put forward. The physical model is established, the results show that detectors are arranged as the form of triangle is more suitable. It can not only satisfy the use requirement but also it is economical and practical. Finally we can conclude that the inlet water temperature 0.5°C higher than dew point temperature is safe and reliable.
机译:在分析天花板辐射散热板上结露的原因和过程的基础上,提出了两种探测器的布置方式。建立了物理模型,结果表明检测器的排列形式为三角形更合适。它不仅可以满足使用要求,而且经济实用。最后我们可以得出结论,进水温度比露点温度高0.5°C是安全可靠的。