After fission or fusion reactor shutdown the activated structure emits decay photons. For maintenance operations the radiation dose map must be established in the reactor building. Several calculation schemes have been developed to calculate the shutdown dose rate. These schemes are widely developed in fusion application and more precisely for the ITER tokamak. This paper presents the rigorous-two-steps scheme implemented at CEA. It is based on the TRIPOLI-4? Monte Carlo code and the inventory code MENDEL. The ITER shutdown dose rate benchmark has been carried out, results are in a good agreement with the other participant.
机译:在裂变或聚变反应堆关闭后,活化的结构发射出衰变光子。为了进行维护操作,必须在反应堆厂房中建立辐射剂量图。已经开发了几种计算方案来计算关闭剂量率。这些方案在融合应用中得到了广泛的发展,更确切地说是在ITER托卡马克中。本文介绍了在CEA实施的严格的两步计划。它基于TRIPOLI-4?蒙特卡洛代码和库存代码MENDEL。已经执行了ITER停工剂量率基准测试,其结果与其他参与者具有很好的一致性。