Subsidence of a non-polished stem in revisions of the hip using impaction allograft

机译:使用撞击同种异体移植术在髋关节翻修中未抛光的茎沉陷

获取原文
           

摘要

We revised 24 consecutive hips with loosening of the femoral stem using impaction allograft and a cemented stem with an unpolished proximal surface. Repeated radiostereometric examinations for up to two years showed a slow rate of subsidence with a mean of 0.32 mm (?2.0 to +0.31). Fifteen cases followed for a further year showed the same mean subsidence after three years, indicating stabilisation. A tendency to retroversion of the stems was noted between the operation and the last follow-up. Retroversion was also recorded when displacement of the stem was studied in ten of the patients after two years. Repeated determination of bone mineral density showed an initial loss after six months, followed by recovery to the postoperative level at two years. Defects in the cement mantle and malalignment of the stem were often noted on postoperative radiographs, but did not correlate with the degrees of migration or displacement. After one year, increasing frequency of trabecular remodelling or resorption of the graft was observed in the greater trochanter and distal to the tip of the stem. Cortical repair was noted distally and medially (Gruen regions 3, 5 and 6). Migration of the stems was the lowest reported to date, which we attribute to the improved grafting technique and to the hardness of the graft.
机译:我们用同种异体植骨法和股骨柄近端表面未抛光的股骨柄松动,对24个连续髋关节进行了翻修。重复进行了长达两年的放射线立体检查,发现沉降速度缓慢,平均值为0.32毫米(?2.0至+0.31)。随后三年又有15例在三年后显示出相同的平均沉降,表明情况稳定。在手术和最后一次随访之间发现了茎逆行的趋势。在两年后的十名患者中研究了茎的移位时也记录了逆行。重复测定骨矿物质密度显示六个月后出现最初的损失,然后在两年后恢复到术后水平。术后X线片上通常会注意到骨水泥套的缺陷和茎的错位,但与迁移或移位的程度无关。一年后,在大转子和茎尖远端观察到骨小梁重塑或吸收的频率增加。在远端和内侧(Gruen区域3、5和6)注意到皮质修复。茎的迁移是迄今为止报道的最低水平,这归因于改进的嫁接技术和嫁接的硬度。
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号