摘要

Studies using roentgen stereophotogrammetric analysis (RSA) have shown that the femoral components of cemented total hip replacements (THR) migrate distally relative to the bone, but it is not clear whether this occurs at the cement-implant or the cement-bone interface or within the cement mantle. Our aim was to determine where this migration occurred, since this has important implications for the way in which implants function and fail.Using RSA we compared for two years the migration of the tip of the stem with that of the cement restrictor for two different designs of THR, the Exeter and Charnley Elite. We have assumed that if the cement restrictor migrates, then at least part of the cement mantle also migrates.Our results have shown that the Exeter migrates distally three times faster than the Charnley Elite and at different interfaces. With the Exeter migration was at the cement-implant interface whereas with the Charnley Elite there was migration at both the cement-bone and the cement-implant interfaces.
机译:使用伦氏立体摄影测量分析(RSA)的研究表明,骨水泥全髋关节置换术(THR)的股骨成分相对于骨骼向远侧迁移,但尚不清楚这是否发生在骨水泥植入物或骨水泥界面处或骨水泥内水泥地幔。我们的目的是确定这种迁移发生在哪里,因为这对植入物起作用和失败的方式具有重要意义。使用RSA我们比较了两种设计中茎尖和水泥限流器的迁移两年。 THR,埃克塞特(Exeter)和Charnley Elite。我们假设如果水泥限流器迁移,那么至少一部分水泥地幔也会迁移。我们的结果表明,埃克塞特向远侧迁移的速度是Charnley Elite的三倍,并且在不同的界面上。使用埃克塞特时,迁移发生在水泥-植入物的界面处,而使用Charnley Elite时,则在骨水泥和水泥-植入物的界面处都发生了迁移。