The BACTEC 9240 blood culture system with a standard aerobic medium, Plus Aerobic/F, was compared to the BacT/Alert system with a platelet-specific medium, BPA, as a means for detecting bacterial contamination of platelet preparations. One hundred thirteen platelet units seeded with low levels of different bacteria were examined with both systems. In 93 instances, growth was detected first in the BACTEC system; in 12 cases, growth registered first in the BacT/Alert system. Among all comparisons, growth was detected, on average, 1.7 h sooner with the BACTEC system. The differences in length of time to detection were statistically significant.
机译:将具有标准需氧培养基Bplus的BACTEC 9240血液培养系统与具有血小板特异性培养基BPA的BacT / Alert系统进行了比较,以此作为检测血小板制品细菌污染的方法。用这两种系统检查了113个接种有少量不同细菌的血小板单位。在93个实例中,首先在BACTEC系统中检测到了生长;在12个案例中,增长首先在BacT / Alert系统中记录。在所有比较中,使用BACTEC系统平均可早1.7小时检测到生长。检测时间长度的差异具有统计学意义。