In steel and concrete composite structures, it is unfavourable to install many headed studs or perfobond ribs with narrow spacings at the joints. To solve this problem, a new type of a mixed shear connector was developed by combining a headed stud and perfobond rib at the same steel beam flange. In this paper, totally nine push-out tests were conducted. The main purpose was to compare the failure mode and the load-slip behavior of the headed stud, perfobond rib, and mixed shear connector. Furthermore, 19 nonlinear finite element simulations were performed. The effects of connector dimension and material properties on the structural behaviors of mixed shear connectors were studied. Based on the experimental and parametric study, an analytical equation was finally proposed to evaluate the shear capacity of perfobond rib with a headed stud mixed shear connector.
机译:在钢和混凝土复合结构中,不利于在接头处安装许多带狭窄的间距的头部铆钉或穿孔肋。为了解决这个问题,通过在同一钢梁法兰处组合头部螺柱和穿孔肋来开发一种新型的混合剪切连接器。在本文中,进行了全部九次推出测试。主要目的是比较头部螺柱,穿孔肋和混合剪切连接器的故障模式和负载滑移行为。此外,进行了19个非线性有限元模拟。研究了连接器尺寸和材料特性对混合剪切连接器结构行为的影响。基于实验和参数研究,最终提出了一种分析方程来评估穿着头螺柱混合剪切连接器的穿孔肋的剪切能力。