In-situ measurements of a case study building located in Riga old town near the river Daugava has been carried out in this work. Performed measurements are moisture level of historic masonry, and interstitial monitoring of temperature and relative humidity between the layers of internal insulation and external wall. Obtained results are compared with outdoor weather data. Results show that during the cold months of the year no rising damp problem. No interstitial condensation under the internal insulation, and no risk of mold growth occur. However, the fa?ade of the building tends to be highly influenced by the outdoor weather, and the moisture of the masonry increases during the rain load events.
机译:在这项工作中,位于River Daugava附近的里加老城区的案例研究建筑的原位测量已经进行了。进行的测量是历史砌体的水分水平,以及内部绝缘层层和外墙层之间的温度和相对湿度的间隙监测。获得的结果与室外天气数据进行比较。结果表明,在一年中的寒冷月份没有上升的潮湿问题。内部绝缘下没有间质凝聚,并且没有发生霉菌生长的风险。然而,建筑物的ADE往往受到室外天气的高度影响,并且在雨部载荷事件期间砌体的水分增加。