...
首页> 外文期刊>Atmospheric Chemistry and Physics Discussions >20 years of ClO measurements in the Antarctic lower stratosphere
【24h】

20 years of ClO measurements in the Antarctic lower stratosphere

机译:在南极较低平流层中20年的CLO测量

获取原文
           

摘要

We present 20?years (1996–2015) of austral springtime measurements of chlorine monoxide (ClO) over Antarctica from the Chlorine Oxide Experiment (ChlOE1) ground-based millimeter wave spectrometer at Scott Base, Antarctica, as well 12?years (2004–2015) of ClO measurements from the Aura Microwave Limb Sounder (MLS). From August onwards we observe a strong increase in lower stratospheric ClO, with a peak column amount usually occurring in early September. From mid-September onwards we observe a strong decrease in ClO. In order to study interannual differences, we focus on a 3-week period from 28?August to 17?September for each year and compare the average column ClO anomalies. These column ClO anomalies are shown to be highly correlated with the average ozone mass deficit for September and October of each year. We also show that anomalies in column ClO are strongly anti-correlated with 30?hPa temperature anomalies, both on a daily and an interannual timescale. Making use of this anti-correlation we calculate the linear dependence of the interannual variations in column ClO on interannual variations in temperature. By making use of this relationship, we can better estimate the underlying trend in the total chlorine (Cly??=??HCl?+?ClONO2 + HOCl?+?2??×??Cl2?+?2??×??Cl2O2 + ClO?+?Cl). The resultant trends in Cly, which determine the long-term trend in ClO, are estimated to be ?0.5?±?0.2, ?1.4?±?0.9, and ?0.6?±?0.4?%?year?1, for zonal MLS, Scott Base MLS (both 2004–2015), and ChlOE (1996–2015) respectively. These trends are within 1σ of trends in stratospheric Cly previously found at other latitudes. The decrease in ClO is consistent with the trend expected from regulations enacted under the Montreal Protocol.
机译:我们在南极洲(Chloe1)地基毫米波光谱仪在南极洲,南极洲(Chloe1)在南极洲,南极洲(Chloe1)南极洲的澳洲春天(1996-2015) 2015年)来自光环微波肢体发声器(MLS)的CLO测量。从8月开始,我们观察到较低的平流层CLO的强烈增加,峰值柱量通常发生在9月初。从9月中旬开始,我们观察CLO的强劲下降。为了研究续年差异,我们将关注3周的时间从28岁?8月至17日?9月每年9月,并比较平均列Clo异构体。这些列Clo异常被证明与每年9月和10月的平均臭氧质量赤字高度相关。我们还表明,列ClO中的异常与每日和际时间尺度的30?HPA温度异常强烈反相关。利用这种反相关,我们计算了柱CLO持续变化的线性依赖性在温度依赖性变化。通过利用这种关系,我们可以更好地估计总氯气中的潜在趋势(Cly ?? = ?? HCl?+?Clono2 + Hocl?+ 2 ??×α×+?2?2××? ?CL2O2 + CLO?+?CL)。确定CLO中长期趋势的CLY所产生的趋势估计是?0.5?±0.2,?1.4?±?0.9和?0.6?±0.4?%?年?1,为Zonal MLS,Scott Base MLS(2004-2015)和Chloe(1996-2015)。这些趋势在于以前发现的其他纬度地区发现的平坦散射体的趋势范围内。 CLO的减少与在蒙特利尔议定书中颁布的规定预期的趋势一致。
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号