Automated Breast Ultrasound: Interobserver Agreement, Diagnostic Value, and Associated Clinical Factors of Coronal-Plane Image Features

机译:自动乳房超声:Interobserver协议,诊断价值和冠状平面图像特征的相关临床因素

获取原文
           

摘要

OBJECTIVE:To evaluate the interobserver agreement, diagnostic value, and associated clinical factors of automated breast ultrasound (ABUS) coronal features in differentiating breast lesions.MATERIALS AND METHODS:This study enrolled 457 pathologically confirmed lesions in 387 female (age, 46.4 ± 10.3 years), including 377 masses and 80 non-mass lesions (NMLs). The unique coronal features, including retraction phenomenon, hyper- or hypoechoic rim (continuous or discontinuous), skipping sign, and white wall sign, were defined and recorded. The interobserver agreement on image type and coronal features was evaluated. Furthermore, clinical factors, including the lesion size, distance to the nipple or skin, palpability, and the histological grade were analyzed.RESULTS:Among the 457 lesions, 296 were malignant and 161 were benign. The overall interobserver agreement for image type and all coronal features was moderate to good. For masses, the retraction phenomenon was significantly associated with malignancies (p 0.001) and more frequently presented in small and superficial invasive carcinomas with a low histological grade (p = 0.027, 0.002, and 0.001, respectively). Furthermore, continuous hyper- or hypoechoic rims were predictive of benign masses (p 0.001), whereas discontinuous rims were predictive of malignancies (p 0.001). A hyperechoic rim was more commonly detected in masses more distant from the nipple (p = 0.027), and a hypoechoic rim was more frequently found in large superficial masses (p 0.001 for both). For NMLs, the skipping sign was a predictor of malignancies (p = 0.040).CONCLUSION:The coronal plane of ABUS may provide useful diagnostic value for breast lesions.Copyright ? 2020 The Korean Society of Radiology.
机译:目的:评价乳房病变的自动乳房超声(Abus)冠状特征的Interobserver协议,诊断价值和相关临床因素.877女性(年龄,46.4±103岁),本研究注册了457例病理证实病变),包括377个质量和80个非质量病变(NML)。定义并记录了独特的冠状特征,包括缩回现象,超级或不连续的rim(连续或不连续的),跳过标志和白色墙标志。评估了图像类型和冠状功能的Interobserver协议。此外,分析了临床因素,包括病变尺寸,与乳头或皮肤的距离,可触及和组织学等级。结果:在457个病变中,296例恶性和161人是良性的。图像类型的整体interobserver协议和所有冠状功能都适中。对于群众来说,缩回现象与恶性肿瘤有显着相关(P <0.001),并且更常见于组织学等级(P = 0.027,0.002和<0.001分别)的小而浅表侵入性癌中。此外,连续的超级或低聚轮辋预测良性质量(P <0.001),而不连续的轮辋是对恶性肿瘤的预测性(P <0.001)。在从乳头的肿块中更常见地检测到高档轮辋(P = 0.027),并且在大浅表质量中更常见的次焦螺旋缘(两者为P <0.001)。对于NMLS,跳过符号是恶性肿瘤的预测因子(P = 0.040)。结论:ABU的冠状面可能为乳房病变提供有用的诊断价值。 2020韩国放射学会。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号