BACKGROUND:Marginal fit is the most important criterion in the evaluation of the clinical acceptability of fixed restorations. Due to cement solubility and plaque retention, marginal gaps are potentially harmful to both the teeth and the periodontal tissues.OBJECTIVES:The aim of the study was to investigate the accuracy of the fit of dental metal-ceramic bridges manufactured with the use of direct metal laser sintering (DMLS), and to explore the effects of porcelain firing on the marginal, axial and occlusal fit of metal-ceramic frameworks.MATERIAL AND METHODS:The study involved 10 patients with 3-unit metal-ceramic restorations produced using the DMLS technique. Using the silicone replica technique, we examined the marginal, axial and occlusal fit of the dental bridges before and after ceramic firing. The Shapiro-Wilks normality test and Student's paired t?test were implemented to analyze the mean differences in the marginal, axial and occlusal fit of the restorations before and after ceramic firing. A 95% confidence interval (CI) and discrepancy values at the level of 1% and 0.1% (p 0.05) were applied.RESULTS:All the mean values of the measurements of marginal (156.08 μm), axial (95.75 μm) and occlusal (252.83 μm) gaps were lower before ceramic veneering than after ceramic veneering, when the mean value for the marginal gap was 178.17 μm, for the axial gap - 106.75 μm and for the occlusal gap - 266.00 μm.CONCLUSIONS:Porcelain firing caused no statistically significant differences in the discrepancy values of marginal, axial and occlusal fit. For clinical application, further improvement of the DMLS system is highly recommended. Marginal gaps in DLSM bridges significantly exceed the permissible inaccuracy values of 100-120 μm for prosthetic restorations.
机译:背景:边缘契合是评估固定修复临床可接受性最重要的标准。由于水泥溶解性和斑块潴留,边缘间隙可能对牙齿和牙周组织的潜在有害。目的:该研究的目的是研究用直接金属制造的牙科金属 - 陶瓷桥的拟合的准确性激光烧结(DMLS),并探讨瓷器射击对金属陶瓷框架的边缘,轴向和咬合拟合的影响。材料和方法:研究涉及10例使用DMLS技术生产的3单位金属陶瓷修复件。使用硅胶副本技术,我们检查了陶瓷射击前后牙科桥梁的边缘,轴向和咬合拟合。 Shapiro-Wilks正常测试和学生配对T?进行了测试,以分析陶瓷烧制前后修复后的边缘,轴向和咬合拟合的平均差异。应用95%的置信区间(CI)和差异值为1%和0.1%(p> 0.05)。结果:边缘(156.08μm),轴向(95.75μm)和轴向的所有平均值在陶瓷嵌体之前比陶瓷嵌合件在陶瓷嵌合之后的粘连胶囊胶凝率低,当边缘间隙的平均值为178.17μm,用于轴向间隙 - 106.75μm和咬合间隙 - 266.00μm.conclusions:瓷器射击造成的边缘,轴向和咬合贴合的差异值差异差异。对于临床应用,强烈建议使用进一步改进DMLS系统。对于假体修复,DLSM桥梁中的边缘间隙明显超过100-120μm的允许不准确值。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号