Coronary CT radiation dose reduction strategies at an Australian Tertiary Care Center – improvements in radiation exposure through an evidence‐based approach

机译:澳大利亚三级护理中心的冠状动脉综合减排策略 - 通过基于证据的方法改进辐射暴露

获取原文
           

摘要

Introduction Coronary CT Angiography (CCTA) is a rapidly increasing technique for coronary imaging; however, it exposes patients to ionising radiation. We examined the impact of dose reduction techniques using ECG‐triggering, kVp/mAs reduction and high‐pitch modes on radiation exposure in a large Australian tertiary CCTA service. Methods Data on acquisition modes and dose exposure were prospectively collected on all CCTA scans from November 2009 to March 2014 at an Australian tertiary care centre. A dose reduction algorithm was developed using published techniques and implemented with education of medical staff, radiographers and referrers. Associations of CCTA acquisition to radiation over time were analysed with multivariate regression. Specificity in positive CCTA was assessed by correlation with invasive coronary angiography. Results 3333 CCTAs were analysed. Mean radiation dose decreased from 8.4?mSv to 5.3, 4.4, 3.7, 2.9 and 2.8?mSv (P??0.001) per year. Patient characteristics were unchanged. Dose reduction strategies using ECG‐triggering, kVp/mAs reduction accounted for 91% of the decrease. High‐pitch scanning reduced dose by an additional 9%. Lower dose was independently related to lower kVp, heart rate, tube current modulation, BMI, prospective triggering and high‐pitch mode (P??0.01). CCTA specificity remained unchanged despite dose reduction. Conclusion Implementation of evidence‐based CCTA dose reduction algorithm and staff education programme resulted in a 67% reduction in radiation exposure, while maintaining diagnostic specificity. This approach is widely applicable to clinical practice for the performance of CCTA.
机译:引言冠状动脉CT血管造影(CCTA)是一种迅速增加的冠状动脉成像技术;然而,它使患者暴露于电离辐射。我们检查了使用ECG触发,KVP / MAS减少和高俯仰模式对大型澳大利亚大学CCTA服务的辐射曝光的影响。方法从2009年11月到2014年11月,在澳大利亚第三节护理中心的所有CCTA扫描上预先收集了收购模式和剂量暴露的数据。使用已发布的技术开发了一种剂量还原算法,并通过医务人员,放射照报者和推荐人进行了。通过多元回归分析CCTA收购随时间辐射的关联。通过与侵袭性冠状动脉造影的相关性评估阳性CCTA的特异性。结果分析了3333中的CCTA。平均辐射剂量从8.4ΔMSV降低至5.3,4.4,3.7,2.9和2.8?MSV每年(P?<0.001)。患者特征不变。使用ECG触发的剂量减少策略,KVP / MAS减少占降低的91%。高间距扫描减少剂量额外9%。较低剂量与较低的KVP,心率,管电流调制,BMI,前瞻性触发和高间距模式独立相关(P?<?0.01)。尽管减少了CCTA特异性,但仍保持不变。结论基于证据的CCTA剂量减少算法和员工教育计划导致辐射暴露的67%,同时保持诊断特异性。这种方法广泛适用于CCTA性能的临床实践。

著录项

获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号