A sectoral diagnosis method for open switch faults of inverter-fed permanent magnet synchronous motor (PMSM) drives have been described. The proposed diagnosis method defines separate residuals for each of the six switches as a sectoral average of the difference between a reference and measured pole voltage instead of direct use of the instantaneous difference, which has varying AC quantity within one cycle of rotation. How to determine plausible thresholds is described and the effectiveness and limitation of the proposed method are analysed. Several sets of experimental results validate the detection and isolation capability of the proposed method.
机译:已经描述了一种用于逆变器式永磁同步电动机(PMSM)驱动器断路故障的扇区诊断方法。提出的诊断方法将六个开关中的每个开关的单独残差定义为参考电压和测得的极电压之间的差异的扇区平均值,而不是直接使用瞬时差异,因为瞬时差异在一个旋转周期内具有变化的交流量。描述了如何确定合理的阈值,并分析了该方法的有效性和局限性。几组实验结果验证了该方法的检测和隔离能力。