首页> 外文期刊>Electric power systems research >Variations in harmonic voltage at the sub-10-minute time scale
【24h】

Variations in harmonic voltage at the sub-10-minute time scale

机译:10分钟时间尺度谐波电压的变化

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents the statistical analysis of variations in harmonic voltage in the time scale between 1 second and 10 min, a time scale that is rarely considered in studies but that is of relevance for incorrect operation of enduser equipment. The paper also introduces a set of novel power-quality indices quantifying these variations and it gives recommendations on how to include these indices in the power-quality-monitoring framework provided by IEC 61000?4?30. The statistics and the illustration of the novel indices are based on measurements of harmonic 2 through 40 with 1-second time resolution at 154 locations in 16 countries. The proposed power-quality indices are a compromise between storing large amounts of raw data with high time resolution, resulting in the different big-data challenges, and completely neglecting this time scale. Two important findings from this paper are that this time scale should not be completely neglected and that information on this time scale can be recorded without excessive increase in the need for data transmission and storage.
机译:本文介绍了1秒和10分钟的时间尺度谐波电压变化的统计分析,这是在研究中很少考虑的时间标度,但是对于终端用主义设备的不正确操作是相关的。本文还介绍了一组新颖的电力质量指标,量化了这些变化,并提出了关于如何在IEC 61000提供的电力 - 质量监测框架中包含这些指数的建议书4?30。统计数据和新颖指数的插图基于164个国家的154个位置的1秒时间分辨率的谐波2至40的测量。所提出的电力质量指标在存储大量原始数据之间的折衷,高度分辨率,导致不同的大数据挑战,并且完全忽略了这一时间尺度。本文的两个重要发现是,不应完全忽略该时间尺度,并且可以记录有关此时间级的信息而不会过度增加数据传输和存储。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号