In this paper, a new solution algorithm based on a multiple gradient summation (MGS) and differential evolution (DE) approach for optimal three-phase active power line conditioners (APLCs) installation in unbalanced distribution systems is proposed. The active power line conditioners installation problem considers the individual and total harmonic voltage distortions as well as the commercially available discrete sizes of the APLCs limits to minimize the total sizes of three-phase APLCs. The imbalance of systems resulting from using asymmetrical connection transformers was taken into account. The effectiveness of the proposed method was demonstrated by its application to a 23-bus unbalanced radial distribution system.
机译:本文提出了一种基于多重梯度求和(MGS)和差分进化(DE)方法的新解决方案算法,用于在不平衡配电系统中安装最佳的三相有功电力线调节器(APLC)。有功功率线路调节器的安装问题考虑了单个和总谐波电压失真以及APLC的市售离散尺寸限制,以最大程度地减小三相APLC的总尺寸。考虑了使用非对称连接变压器导致的系统不平衡。该方法在23总线不平衡径向分配系统中的应用证明了该方法的有效性。