As transmission grid assets are being pushed more and more towards their limits, the use of WAM systems to supervise and maintain high voltage grid stability has won significant attention. The aim of this article was to show the feasibility of WAM systems. First, it proved the advantages of WAMS over the conventional SCADA/EMS systems by using dynamic measurement data from PMUs. PMU implementation, PMU Placement techniques and a number of power system applications concerning monitoring, protection emergence control were subsequently discussed. Frequency instability assessment, voltage instability assessment were also covered. It is virtually established that Wide Area Monitoring extends the capability of existing local monitoring, protection and control equipment to further levels of asset utilization.
机译:随着输电网资产越来越多地推向极限,使用WAM系统来监督和维持高压电网的稳定性备受关注。本文的目的是展示WAM系统的可行性。首先,它通过使用来自PMU的动态测量数据证明了WAMS优于常规SCADA / EMS系统的优势。随后讨论了PMU的实施,PMU的放置技术以及有关监视,保护应急控制的许多电力系统应用。频率不稳定性评估,电压不稳定性评估也包括在内。实际上,广域监视已将现有的本地监视,保护和控制设备的功能扩展到资产利用率的更高水平。

著录项

  • 来源
    《Electrical India》 |2010年第1期|130-132134-136138141-143|共10页
  • 作者单位

    Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India;

    Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India;

    Department of Electrical Engineering, Indian Institute of Technology Madras, Chennai, India;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号