Failure analysis of a permanent-magnet synchronous motor drive in field-weakening operation

机译:弱磁运行中的永磁同步电动机驱动器的故障分析

获取原文
获取原文并翻译 | 示例
           

摘要

Permanent-magnet machines are widely used in broad-rang speeds applications like in electric vehicles. For these purposes the field-weakening control method it's one of the most common ways to achieve the required speed. When a permanent-magnet synchronous motor (PMSM) works under field weakening operation the stator voltage can reach very high values, if a failure occurs in this operation the back-EMF could damage the inverter causing a huge problem in terms of machine operator's security and material damage of the drive. This research work analyses the electric impact of failures that may occur in the switching devices and DC-Link of the drive. For this purpose we simulated the entire system, PMSM plus converter, working under a field-weakening operation.
机译:永磁电机广泛用​​于电动汽车等大范围速度应用中。出于这些目的,弱磁场控制方法是达到所需速度的最常用方法之一。当永磁同步电动机(PMSM)在弱磁操作下工作时,定子电压可能会达到很高的值,如果在此操作中发生故障,反电动势可能会损坏逆变器,从而在机器操作员的安全性和安全性方面造成巨大问题。驱动器的物质损坏。这项研究工作分析了驱动器的开关设备和DC-Link中可能发生的故障的电气影响。为此,我们模拟了整个系统,即PMSM plus转换器,它在弱磁场下工作。