首页> 外文期刊>Energy and Buildings >Regression-based approach to modeling emerging HVAC technologies in EnergyPlus: A case study using a Vuilleumier-cycle heat pump
【24h】

Regression-based approach to modeling emerging HVAC technologies in EnergyPlus: A case study using a Vuilleumier-cycle heat pump

机译:基于回归的EnergyPlus中新兴HVAC技术建模方法:使用Vuilleumier循环热泵的案例研究

获取原文
获取原文并翻译 | 示例
           

摘要

This paper presents a regression-based approach for modeling emerging heating, ventilation, and airconditioning (HVAC) technologies using the user-defined coil object in the building simulation software EnergyPlus. The approach can use output from HVAC system models or experimental data to create regression-based performance curves, which are then used within the building simulation. The regression approach is an alternative to modeling new HVAC technologies directly in EnergyPlus or performing co-simulation with a system model in a separate program. The proposed approach connects component and system level designs, and their associated performance, with annual energy use and costs in a variety of climates. This study focused on a Vuilleumier-cycle heat pump for a commercial building. We describe (1) the design and modeling of this system, (2) methods for translating this performance into a simplified model in EnergyPlus, and (3) building energy simulation results in United States climate zones 4-6. The results predict that the Vuilleumier-cycle heat pump will use 34 to 44% less source heating energy than an 80% efficient gas furnace, and more source cooling energy than a SEER 13 air conditioner. Total energy costs are lower when electricity prices are high and natural gas prices are low. (C) 2019 Elsevier B.V. All rights reserved.
机译:本文提出了一种基于回归的方法,用于在建筑仿真软件EnergyPlus中使用用户定义的线圈对象对新兴的采暖,通风和空调(HVAC)技术进行建模。该方法可以使用HVAC系统模型的输出或实验数据来创建基于回归的性能曲线,然后将其用于建筑仿真中。回归方法是直接在EnergyPlus中为新的HVAC技术建模或在单独的程序中与系统模型执行联合仿真的替代方法。所提出的方法将组件和系统级设计及其相关性能与各种气候下的年度能源使用和成本联系起来。这项研究的重点是用于商业建筑的Vuilleumier循环热泵。我们描述(1)该系统的设计和建模,(2)在EnergyPlus中将这种性能转换为简化模型的方法,以及(3)在美国4-6气候带中建立能源模拟结果。结果预测,Vuilleumier循环热泵将比高效80%的煤气炉使用的源热能少34%至44%,比SEER 13空调器使用的源冷能更多。当电价高而天然气价低时,总能源成本较低。 (C)2019 Elsevier B.V.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号