首页> 外文期刊>IEEE Transactions on Energy Conversion >Test and simulation of network dynamic response using SSFR and RTDR derived synchronous machine models
【24h】

Test and simulation of network dynamic response using SSFR and RTDR derived synchronous machine models

机译:使用SSFR和RTDR导出的同步机模型测试和仿真网络动态响应

获取原文
获取原文并翻译 | 示例
           

摘要

The comparative testing of four 60 Hz two-pole generators indicates practical advantages for the SSFR (standstill frequency response) method over the RTDR (rotating time-domain response) method when synchronous machine models are to be synthesized from test data for network dynamic performance analysis. Manufacturer-provided data are compared to SSFR and RTDR derived parameters. All adequately duplicate synchronization, load rejection, and line switching tests. Deterministic sensitivity of CFCT (critical fault clearing time) to selected machine parameters is reported.
机译:四个60 Hz两极发电机的对比测试表明,当要从测试数据中合成同步电机模型进行网络动态性能分析时,SSFR(静止频率响应)方法比RTDR(旋转时域响应)方法具有实际优势。 。将制造商提供的数据与SSFR和RTDR得出的参数进行比较。所有足够重复的同步,负载抑制和线路切换测试。报告了CFCT(关键故障清除时间)对所选机器参数的确定性敏感性。