Degradation of interturn insulation caused by repetitive surges is studied for coils in three motors stators. In each stator, the coils are isolated and divided into several groups. Breakdown voltages of coils in one group are measured for 0.1 mu s risetime impulses and the average breakdown voltage of these unaged coils is determined. Coils in the other groups are first subjected to a number (1000 to 8000) of surges with magnitudes of 3.0 to 7.8 pu, and then the impulse breakdown voltages for these aged coils are measured and compared with those for the unaged coils. The results of the measurements on two stators showed no evidence of degradation of turn insulation by surges. There is an indication of surge aging of the turn insulation for one stator. Surge magnitudes capable of causing detectable aging of turn insulation appear to be higher than those likely to occur at normally operating utility motors. The existence of a threshold value of surge magnitude required to produce aging effects is a possible hypothesis.
机译:对三个电动机定子中的线圈,研究了由重复电涌引起的匝间绝缘性能的下降。在每个定子中,线圈被隔离并分成几组。对一组线圈的击穿电压进行0.1 µs上升时间脉冲的测量,并确定这些未老化线圈的平均击穿电压。首先对其他组的线圈进行多次(1000至8000)浪涌,幅度为3.0至7.8 pu,然后测量这些老化的线圈的脉冲击穿电压,并将其与未老化的线圈进行比较。在两个定子上的测量结果表明,没有迹象表明电涌会导致匝间绝缘性能下降。有迹象表明一个定子的线圈绝缘浪涌老化。能够引起匝间绝缘可检测到老化的浪涌幅度似乎高于正常运行的通用电机可能出现的浪涌幅度。一个可能的假设是,存在产生老化效应所需的浪涌幅度阈值。