The new 7,000-sq-ft dewatering building at the Water Resources Recovery Facility in Williston, N.D., contains several pumps, liquid storage tanks and a sludge tank. The project site is underlain by 4 ft to 5 ft of silty lean clay fill, overlying very stiff fat to lean clay; groundwater levels are anticipated to be about 9 ft below the ground surface. The mat foundation pressure beneath the new building exceeded 4.3 ksf. Settlement analyses indicated 3 in. to 4 in. of settlement. Serviceability issues required that the new building settle no more than 1.5 in. so the client was faced with either supporting the building on a deep foundation system or using a ground improvement technology.
机译:位于北卡罗来纳州威利斯顿的水资源回收设施的新的7,000平方英尺的脱水大楼包含数个泵,液体储罐和污泥罐。该项目场地位于4英尺至5英尺的粉质贫瘠粘土填充层之下,上面覆盖着非常坚硬的脂肪至贫瘠粘土;地下水位预计在地表以下约9英尺。新建筑物下方的垫层基础压力超过4.3 ksf。沉降分析表明沉降为3英寸至4英寸。可服务性问题要求新建筑物的沉降量不得超过1.5英寸,因此客户将面临在深基础系统上为建筑物提供支持或使用地面改良技术的麻烦。