There are several questions to be answered in relation to the thermocouple application described in the recent contribution to this journal by Jha et al. [1]. First, the 'probe diameter' of 1 mm -is that the bead diameter of a bare-wire thermocouple or the sheath diameter of a mineral-insulated metal sheathed (MIMS) thermocouple? This information is important. We are told on p. 1983 that it is type K, yet on p. 1985 we are told that it was NiCr-Ni. Type K is NiCr-NiAl: none of the letter-designated ther-mocouples has a thermoelement of nickel alone. So this point needs clearing up.
机译:关于热电偶的应用,有几个问题需要解答。 [1]。首先,“探针直径”为1毫米-是裸线热电偶的磁珠直径还是矿物绝缘金属护套(MIMS)热电偶的护套直径?此信息很重要。我们在p上被告知。 1983年,它是K型,但在p。 1985年,我们被告知是NiCr-Ni。 K型为NiCr-NiAl:字母指定的热电偶都没有单独的镍热电偶。因此,这一点需要解决。