首页> 外文期刊>Gynecological Surgery >Strength of sliding knots in multifilament resorbable suture materials
【24h】

Strength of sliding knots in multifilament resorbable suture materials

机译:复丝可吸收缝线材料中打结的强度

获取原文
获取原文并翻译 | 示例
           

摘要

Experimental laboratory study was made to test the knot integrity of identical, non-identical and parallel sliding knots, with three and five throws, made with synthetic resorbable multifilament suture materials. The knots were made with Novosyn (polyglactin 612), Safil (polyglycolic acid), Vicryl (polyglactin 612) and Vicryl plus (polyglactin 910 + triclosan), all with suture size: 3-0 USP. Per material 10 knots for every kind of knot were tested in a tensiometer, resulting in a total of 240 tests. Sliding knots with three throws were compared with the five throw sliding knots, and a comparison of the loop-holding capacities (LHC) of the different suture materials was made. Differences in suture material, knot type, and number of throws in the knot had a remarkable effect on knot performance. Adding two extra throws to a three throw non-identical or parallel sliding knot resulted in significantly more reliable knots (P 0.05). In identical sliding knots, this effect was not seen, but these knots showed low LHCs, indicating poor knot reliability. Compared to the other suture materials, Safil showed significantly lower LHCs. Most of the mean LHCs of the various knots with Vicryl, Vicryl Plus or Novosyn were not statistically different from each other. Identical sliding knots appeared to be very unreliable, especially when made with three throws. Non-identical and parallel slipknots with five throws demonstrated superior knot integrity compared with the same knot types with three throws. Safil had inferior knot properties as compared to the other materials, but Vicryl, Vicryl Plus and Novosyn behaved virtually the same. The type of knot and the use of different suture materials have important influence on the integrity of the knot. A high knot reliability is nowadays all the more important because of the frequent use of resorbable suture materials. The suture gradually loses strength during the resorption process, so that an extra margin of safety neutralizes the effect of this process.
机译:进行了实验性实验室研究,以测试由合成可吸收多丝缝合线材料制成的三,五掷相同,不相同和平行的滑动结的结完整性。结由Novosyn(polyglactin 612),Safil(聚乙醇酸),Vicryl(polyglactin 612)和Vicryl plus(polyglactin 910 +三氯生)制成,所有缝合线的尺寸为3-0 USP。每种材料每种结的10节都在张力计中进行了测试,总共进行了240次测试。比较了三掷滑动结和五掷滑动结,并比较了不同缝合线材料的环固持能力(LHC)。缝合材料,打结类型和打结次数的差异对打结性能产生显着影响。在三个不相同或平行的滑动结中增加两个额外的结,则使结更可靠(P <0.05)。在相同的滑动结中,没有看到这种效果,但是这些结显示出较低的LHC,表明结可靠性差。与其他缝线材料相比,Safil的LHC明显降低。具有Vicryl,Vicryl Plus或Novosyn的各种结的大多数平均LHC均无统计学差异。完全相同的滑动结似乎非常不可靠,尤其是三掷时。与具有三个抛出的相同打结相比,具有五个抛出的不相同和平行的活结表现出了更高的结完整性。与其他材料相比,Safil的打结性能较差,但Vicryl,Vicryl Plus和Novosyn的表现几乎相同。结的类型和使用不同的缝合材料对结的完整性有重要影响。由于频繁使用可吸收缝合线材料,如今,高度结可靠性变得尤为重要。缝线在吸收过程中逐渐失去强度,因此额外的安全性抵消了该过程的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号