首页> 外文期刊>Heat Transfer Engineering >Experimental Investigation on the Performance of Condenser for Charge Reduction of HC-290 in a Split Air-Conditioning System
【24h】

Experimental Investigation on the Performance of Condenser for Charge Reduction of HC-290 in a Split Air-Conditioning System

机译:拆分空调系统中HC-290电荷减少电凝块性能的实验研究

获取原文
获取原文并翻译 | 示例
           

摘要

HC-290 is a promising alternative for HCFC-22, which is an ozone depleting substance under Montreal Protocol. However, HC-290 charge is to be reduced because of its flammability. The objective of this study was to reduce the charge quantity of HC-290 in a split air conditioner, which was originally designed for HCFC-22. The effect of charge reduction on the performance of the HC-290 split air-conditioning system was studied experimentally by varying condenser tube diameter, length of capillary tube, and condenser air face velocity. Initially, simulation study was conducted using ART simulation software. In accordance with the simulation results, a 5.25 kW split air conditioner was modified and experimentally tested with HC-290 in a psychrometric test facility under standard test conditions as per IS 1391 part 2. The condenser tube diameter was reduced from 12.7 mm to 6.35 mm, while the length of capillary tube was increased from 650 mm to 820 mm with enhanced condenser air face velocities. It was found that with 300 g of HC-290 charge, the performance parameters such as cooling capacity, power consumption, and coefficient of performance were better than the baseline test with HCFC-22 in all conditions tested.
机译:HC-290是HCFC-22的有希望的替代方案,其是蒙特利尔方案下的臭氧消耗物质。然而,由于其易燃性,将减少HC-290电荷。本研究的目的是将最初设计用于HCFC-22的分体式空调中HC-290的电荷量。通过改变冷凝器管直径,毛细管的长度和冷凝器空气面速度,通过实验研究了对HC-290分流空调系统性能的影响。最初,使用艺术仿真软件进行仿真研究。根据模拟结果,根据标准试验条件,用HC-290进行5.25kW分离空调,并在标准试验条件下在标准试验条件下进行实验测试,如1391部分。冷凝器管直径从12.7毫米降低至6.35毫米,虽然毛细管长度从650mm升高到820mm,但具有增强的冷凝器空气面速度。结果发现,对于300克HC-290电荷,诸如冷却能力,功耗和性能系数的性能参数比在所有条件下测试的HCFC-22的基线试验更好。

著录项

  • 来源
    《Heat Transfer Engineering》 |2020年第18期|1499-1511|共13页
  • 作者单位

    Department of Mechanical Engineering VSB College of Engineering Technical Campus Kinathukadavu Coimbatore Tamil Nadu India;

    Department of Mechanical Engineering College of Engineering Guindy Anna University Chennai Tamil Nadu India;

    Department of Mechanical Engineering SRM Institute of Science and Technology Kattankulathur Chennai Tamil Nadu India;