首页> 外文期刊>Hydro Review Worldwide >The Cracked Generator Rotor Bracket
【24h】

The Cracked Generator Rotor Bracket

机译:裂纹的发电机转子支架

获取原文
获取原文并翻译 | 示例
           

摘要

George worked with an owner's design team on a 40-mw hydro plant. The team was reviewing the water-to-wire contractor's second design for a vertical Francis turbine-generator. The contractor had accepted comments on the first design except for one comment on the generator rotor. Despite the design team's questioning of a flat, steel disc proposed as the connection between the generator shaft and rotor poles, the contractor left it in the design. The design team had questioned the selection of a disc to support the rotor poles, based on lack of precedent and suspicion that severe vibration problems would arise from the lack of rigidity between the shaft and rotor poles. Turbulent flow through the runner when the gates were partially open could induce vibrations in the disc, perhaps enhanced by harmonic interaction with vibrations emanating from the space between the runner and turbine head cover. The design team asked the contractor to provide a precedent for the design.
机译:乔治与业主的设计团队合作设计了40兆瓦的水力发电厂。团队正在审查立式混流式水轮发电机的水线承包承包商的第二个设计。承包商接受了对第一种设计的评论,但对发电机转子的评论除外。尽管设计团队质疑用扁平的钢制圆盘作为发电机轴和转子磁极之间的连接方式,但承包商还是将其保留在设计中。由于缺乏先例和怀疑,轴和转子磁极之间缺乏刚性会导致严重的振动问题,设计团队对选择用于支撑转子磁极的圆盘提出了质疑。当闸门部分打开时,流经转轮的湍流会在圆盘中引起振动,这可能是由于与转轮和涡轮机头盖之间的空间产生的振动产生谐波相互作用而增强的。设计团队要求承包商为设计提供先例。