首页> 外文期刊>IEEE Transactions on Power Electronics >Inductor Current Feedback Active Damping Method for Reduced DC-Link Capacitance IPMSM Drives
【24h】

Inductor Current Feedback Active Damping Method for Reduced DC-Link Capacitance IPMSM Drives

机译:电感电流反馈有源阻尼方法,用于减少DC-Link电容IPMSM驱动器

获取原文
获取原文并翻译 | 示例
           

摘要

The LC resonance between the line inductor and the dc-link film capacitor is an important concern in the reduced dc-link capacitance interior permanent magnet synchronous motor drive system. In this paper, an active damping method based on the virtual damping resistor is applied to suppress the LC resonance and improve the drive system stability. The performance of the damping resistor is analyzed in a systematic level, and possible configurations have been analyzed to obtain the optimal solution, which is proved to be the inductor current feedback (ICF) damping method. In order to realize the equivalent damping effect, the dc-link voltage feedback is applied to emulate the ICF-based active damping method by a step-by-step approach. Meanwhile, the grid voltage distortion will stimulate additional harmonics of the grid current in the reduced dc-link capacitance motor drives. Hence a feedforward compensation method is applied to suppress the grid current distortion arising from the distorted grid voltage, which has not been investigated in the previous related researches. Harmonics of the grid current are reduced and requirements of EN61000-3-2 can be satisfied by applying the proposed method. Experiments on a compressor drive platform equipped with the reduced dc-link capacitance are performed to verify the effectiveness of the proposed method.
机译:线路电感器和DC-Link膜电容器之间的LC谐振是降低的直流连杆电容内部永磁同步电动机驱动系统中的重要关注。在本文中,应用了基于虚拟阻尼电阻的有源阻尼方法来抑制LC谐振并提高驱动系统稳定性。在系统级别分析阻尼电阻的性能,并且已经分析了可能的配置以获得最佳解决方案,这被证明是电感器电流反馈(ICF)阻尼方法。为了实现等效的阻尼效果,施加DC连杆电压反馈以通过逐步的方法模拟基于ICF的有源阻尼方法。同时,电网电压失真将刺激降低的DC连杆电容电动机驱动器中的电网电流的附加谐波。因此,施加前馈补偿方法以抑制来自扭曲的电网电压引起的网格电流失真,这在先前的相关研究中尚未研究。通过应用所提出的方法,可以减少曲线电流的谐波,并且可以满足EN61000-3-2的要求。执行在配备有降低的直流链路电容的压缩机驱动平台上的实验,以验证所提出的方法的有效性。

著录项

  • 来源
    《IEEE Transactions on Power Electronics》 |2019年第5期|4558-4568|共11页
  • 作者单位

    Harbin Inst Technol Sch Elect Engn & Automat Harbin 150001 Heilongjiang Peoples R China;

    Harbin Inst Technol Sch Elect Engn & Automat Harbin 150001 Heilongjiang Peoples R China;

    Harbin Inst Technol Sch Elect Engn & Automat Harbin 150001 Heilongjiang Peoples R China;

    Harbin Inst Technol Sch Elect Engn & Automat Harbin 150001 Heilongjiang Peoples R China;

    Harbin Inst Technol Sch Elect Engn & Automat Harbin 150001 Heilongjiang Peoples R China;

    Harbin Inst Technol Sch Elect Engn & Automat Harbin 150001 Heilongjiang Peoples R China;

  • 收录信息 美国《科学引文索引》(SCI);美国《工程索引》(EI);
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类
  • 关键词

    Active damping; distorted grid voltage; inductor current feedback (ICF); reduced dc-link capacitance;

    机译:主动阻尼;扭曲的电网电压;电感器电流反馈(ICF);降低了直流连接电容;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号