An essential issue concerning short-circuit studies is about how precise short-circuit calculations should be. Simplified procedures have been proposed for many years by International Committees to provide reference methods for manual computation and for the use of rated, rather than operating, equipment data. Recently, dynamic programs have been used to accurately simulate short-circuit currents. Two widely adopted international standards (ANSI/IEEE C37.010.1979 and IEC 909 Standards) are investigated in this paper for comparing and pointing out the most significant differences in methodologies, assumptions, computed currents, and results. An outline of the two standards is presented and a detailed comparison is carried out. The procedures of the two standards are applied to a test network proposed in the IEC 909 Standard. Results of calculations by the two standards are compared using the results of a transient study performed by the EMTP simulation program as a reference basis.
机译:有关短路研究的一个基本问题是短路计算的精确程度。国际委员会已经提出了简化的程序多年,以提供用于手工计算以及使用额定(而不是运行)设备数据的参考方法。最近,动态程序已被用来精确模拟短路电流。本文研究了两个广泛采用的国际标准(ANSI / IEEE C37.010.1979和IEC 909标准),用于比较和指出方法,假设,计算电流和结果方面的最大差异。给出了这两个标准的概述,并进行了详细的比较。这两个标准的过程适用于IEC 909标准中提出的测试网络。使用由EMTP仿真程序执行的瞬态研究的结果作为参考基础,比较了这两个标准的计算结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号