This paper reports the use of an adsorptive voltammetric technique for Pb(Ⅱ) determination using cupferron as a selective complexing agent. After accumulation of the complex onto a hanging mercury drop electrode, the electrode potential was scanned with differential pulse modulation and the reduction current of lead was observed at about -0.5 V. Under optimum conditions (5 × 10~(-4)molL~(-1) cupferron concentration, O.l molL~(-1) acetate buffer (pH 5.5), adsorption at - 50mV for 30s) the detection limit was 5.1 × 10~(-10)molL~(-1). The relative standard deviation of five measurements for low lead concentration was 3.1%. The accuracy of the method was tested by analysing certified reference material (SPS-WW1 Waste Water). Finally, the method was successfully applied to the determination of Pb(Ⅱ) in river water samples without any pretreatments.
机译:本文报道了使用吸附伏安法以铜铁作为选择性络合剂测定Pb(Ⅱ)的方法。将络合物累积到悬挂的汞滴电极上后,用差分脉冲调制扫描电极电势,并在-0.5 V左右观察到铅的还原电流。在最佳条件下(5×10〜(-4)molL〜( -1)铜铁试剂浓度,Ol molL〜(-1)醋酸盐缓冲液(pH 5.5),在-50mV吸附30s)的检测极限为5.1×10〜(-10)molL〜(-1)。低铅浓度的五次测量的相对标准偏差为3.1%。通过分析认证的参考物质(SPS-WW1废水)测试了该方法的准确性。最后,该方法无需任何预处理即可成功地用于测定河水样品中的Pb(Ⅱ)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号