Transient testing methods are widely used for determining the heat transfer coefficients of compact heat exchanger surfaces. The maximum slope method is commonly used for reducing the transient test data. The maximum slope is a function of the "ntu" as well as the longitudinal heat conduction parameter. Normally, the longitudinal heat conduction parameter is estimated, and the maximum slope determined experimentally is used to estimate the ntu. The estimation of longitudinal heat conduction parameter is not easy for complex heat exchanger surfaces. In this paper, a method is presented for estimating the ntu and the longitudinal heat conduction parameter directly from the test data using the maximum slope and the time at the maximum slope. The method has been validated experimentally.
机译:瞬态测试方法被广泛用于确定紧凑型热交换器表面的传热系数。最大斜率方法通常用于减少瞬态测试数据。最大斜率是“ ntu”以及纵向热传导参数的函数。通常,纵向热传导参数是估算值,实验确定的最大斜率用于估算ntu。对于复杂的换热器表面,纵向导热参数的估计并不容易。在本文中,提出了一种使用最大斜率和最大斜率的时间直接从测试数据中估计ntu和纵向热传导参数的方法。该方法已通过实验验证。